Single-stage direct-connected magnetic pump SMZF-D, SMEF-D
Application scope
Single-stage direct-connected magnetic pump SMZF-D, SMEF-D
Technical Parameters
Outlet Diameter | Flow Rate | Head | Required Net Positive Suction Head (NPSH) | Temperature | Pressure Class | Speed | Power |
DN25~DN250 | 0~700m³/h | ~150 m | 0.5~6 m | ~250°C | 2.5~10 MPa | 1450/2950 rpm | Maximum 160 KW |
Structural Features
● OH1 base support and OH2 center support
● Compact structure, small footprint
● Double isolation casing can be adopted to achieve double safety protection, and the first layer isolation casing leakage alarm
● If special needs, a third layer fully enclosed seal can be designed based on the double isolation casing structure
Application Range
Hazardous Media: Liquid chlorine, anhydrous hydrogen fluoride, hydrogen chloride, phosgene, chloromethane, chlorosilane, etc.
Related Products
VS6 vertical cylindrical bag liquid chlorine magnetic pump SDTMMC
VS6 vertical tubular magnetic pump SDTM ZF/MC (semi-underground installation)
OH1, OH2 horizontal slurry magnetic pump SMOF
Vertical mud magnetic pump SMQ